Download 4th International Workshop on Wearable and Implantable Body by Steffen Leonhardt, Thomas Falck, Petri Mähönen PDF

By Steffen Leonhardt, Thomas Falck, Petri Mähönen

This publication comprises papers from the overseas Workshop on Wearable and Implantable physique Sensor Networks, BSN 2007, held in March 2007 on the collage health facility Aachen, Germany. subject matters lined within the quantity comprise new clinical measurements, clever bio-sensing textiles, low-power instant networking, method integration, scientific sign processing, multi-sensor information fusion, and on-going standardization actions.

Show description

Read or Download 4th International Workshop on Wearable and Implantable Body Sensor Networks (BSN 2007): March 26-28, 2007 RWTH Aachen University, Germany (IFMBE Proceedings) PDF

Similar biomedical engineering books

Intelligent and Adaptive Systems in Medicine (Series in Medical Physics and Biomedical Engineering)

Clever and adaptive ideas are quickly getting used in all levels of clinical therapy, from the preliminary analysis to making plans supply and follow-up treatment. to achieve the total power of those strategies, builders and finish clients needs to comprehend either the underlying know-how and the specifics of the clinical software thought of.

Bioimpedance and Bioelectricity Basics, Second Edition

Bioelectricity (or bioelectromagnetism) pertains to the learn of organic electric currents, and bioimpedance bargains with the size of electric conductivity. they're in detail associated with biomedical engineering, with significant importance for improvement of novel scientific units, in addition to the examine of organic rhythms.

Biofluid Dynamics: Principles and Selected Applications

Requiring basically an introductory historical past in continuum mechanics, together with thermodynamics, fluid mechanics, and reliable mechanics, Biofluid Dynamics: rules and chosen purposes comprises evaluate, technique, and alertness chapters to construct a pretty good figuring out of clinical implants and units.

Additional info for 4th International Workshop on Wearable and Implantable Body Sensor Networks (BSN 2007): March 26-28, 2007 RWTH Aachen University, Germany (IFMBE Proceedings)

Sample text

Results The BIS system was tested with different test circuits as well as with several experiments on human volunteers. The commercially available BIS System Xitron Hydra 4200 served as a gold standard. As one test circuit, the official Xitron test dummy was used, which is used to periodically check the accuracy of the medical certified BIS system (Xitron Hydra 4200). Its circuit diagram represents the resistive and capacitive component of the skin in the points where the electrodes are placed as well as the Cole-Cole Model for a 70 Kg 175cm person.

L. Shepherd, and D.

These examples point to the necessity of an exact monitoring of nutritional condition and water balance. g. clothing. g. fat content and water content) of the human body. This data enables conclusions about the person’s health condition. So far, dilution methods have been the gold standard for body composition analysis [2]. Nevertheless, they are time consuming and not suitable for a continuous mobile application. In contrast, BIS allows a fast measurement and its implementation in a portable application [2] but has suffered from non-credibility because of its reported limited accuracy when compared with the gold standard.

Download PDF sample